A transdermal patch is a pharmaceutical dosage form applied to intact skin, in which the active pharmaceutical ingredient (API) is released from the delivery system and permeates through the skin barrier to produce a systemic therapeutic effect. Contact between the formulation and the skin is maintained by adhesive systems, while the formulation components are designed to control drug release and permeation throughout the application period.
Transdermal patches are a characteristic dosage form of the Transdermal Therapeutic System (TTS), also referred to as the Transdermal Drug Delivery System (TDDS). TTS is designed to deliver an API continuously and in a controlled manner through the skin into the systemic circulation over a defined period, thereby maintaining a consistent drug supply during treatment.
The development of TTS aims to overcome certain limitations of oral administration, particularly first-pass metabolism and exposure to the gastrointestinal environment, while exploiting the advantages of controlled and sustained drug release. This provides the foundation for TTS as an approach to developing drug delivery systems capable of maintaining consistent drug delivery.
Based on the physical location of the API within the different structural layers of the patch, TTS can be classified into three main types:
image
Drug-in-Reservoir System (DIR): The API is dissolved in a liquid or gel formulation and contained within a separate reservoir compartment. This compartment is separated from the skin by a rate-controlling membrane and an adhesive layer.
Drug-in-Polymer Matrix System: The API is dissolved or dispersed within a polymer matrix. The release rate depends on the properties of the polymer matrix and the diffusion behavior of the API.
Drug-in-Adhesive System (DIA): The API is dissolved or dispersed directly within the pressure-sensitive adhesive layer. This adhesive layer serves both as the skin-contacting adhesive and as the drug reservoir responsible for drug release.
The basic structure of a transdermal patch consists of a backing layer, a drug-containing layer, a pressure-sensitive adhesive layer, a rate-controlling membrane, and a protective release liner.
Function: The backing layer is the outermost layer of the TTS. It protects the internal layers from physical and chemical influences from the external environment. The backing material must be flexible and conformable, with appropriate barrier properties to limit the diffusion of the API and excipients. In addition, it must be compatible with the API and excipients and meet the required oxygen permeability and water vapor transmission characteristics.
Commonly used backing materials: Polyvinyl materials, polyethylene, polyester, aluminum, and polyolefin.
Function: This layer serves as the reservoir for the API intended for transdermal delivery. The active ingredient may be dissolved or dispersed within a polymer network. It may exist in liquid or gel form within a separate reservoir compartment, or be uniformly dissolved or dispersed within a polymer matrix or adhesive layer.
Components of the drug-containing layer:
Active Pharmaceutical Ingredient (API): The skin acts as a barrier that restricts drug permeation and absorption in transdermal therapeutic systems. Therefore, APIs intended for TTS must possess certain physicochemical properties that enable them to overcome this barrier. Preferred APIs generally have high potency, with a therapeutic dose not exceeding 20 mg/day, an octanol/water partition coefficient (log P) ranging from 1 to 5, a molecular weight below 500 Da, and a melting point below 250 °C. In addition, the API should not cause skin irritation or sensitization.
Polymer Matrix: The polymer matrix serves as the structural backbone of the system, regulating the diffusion rate and encapsulating the API. Polymer selection must ensure compatibility with the API and other formulation components. In addition, properties such as molecular weight and glass transition temperature (Tg) must be appropriate to achieve the desired drug-release characteristics and stability throughout the product's shelf life.
Commonly used polymer excipients:
Natural polymers: Cellulose derivatives, gelatin, shellac, natural rubber, and various gums.
Synthetic polymers: Polyvinyl alcohol (PVA), ethyl cellulose (EC), hypromellose (HPMC), and acrylic polymers, such as partially neutralized polyacrylate.
Pressure-Sensitive Adhesives (PSAs) in DIA systems: Polydimethylsiloxane (PDMS), polyisobutylene (PIB), and acrylic-based adhesives.
Permeation Enhancers: These excipients temporarily modify the intercellular lipid structure, stratum corneum proteins, or the keratin environment to enhance API diffusion through the skin. Permeation enhancers should have no independent pharmacological activity, be non-toxic, non-irritating to the skin and mucous membranes, and not cause incompatibility or interactions with the API or other excipients.
Permeation enhancers are classified into three main groups:
Solvents: Water, alcohols, alkyl methyl sulfoxides, propylene glycol, glycerol, isopropyl myristate, oleic acid, ethyl oleate, decyl oleate, and others.
Surfactants: Sodium lauryl sulfate, polysorbate 80, dodecyl methyl sulfoxide, poloxamers, and others.
Other compounds: Urea, eucalyptol, calcium thioglycolate, soybean casein, and others.
Other excipients: Humectants, preservatives, antioxidants, and pH adjusters.
Function: Pressure-sensitive adhesives are materials responsible for maintaining adhesion between the transdermal patch and the skin surface. They must provide immediate adhesion upon application and maintain sufficient adhesion throughout the intended wear period. They must also exhibit good biocompatibility, cause no skin irritation or sensitization, and be chemically compatible with the API and other excipients.
Commonly used pressure-sensitive adhesive materials: Polyisobutylene (PIB), polydimethylsiloxane (PDMS), pressure-sensitive acrylic adhesives, and naturally derived adhesive materials.
Function: This membrane is typically incorporated into reservoir-type designs to regulate the diffusion rate of the API toward the skin according to defined release kinetics.
Commonly used rate-controlling membrane materials: Ethylene-vinyl acetate (EVA), silicone elastomers, polyurethane, polyisobutylene, polyacrylates, and pressure-sensitive adhesive materials.
Function: The protective release liner is considered part of the primary packaging system of the transdermal patch. Since it comes into contact with the API, excipients, and/or pressure-sensitive adhesive layer, it must be chemically inert and must not adversely affect drug release or absorption from the patch.
Commonly used release liner materials: Paper fabrics, polyethylene, and polyvinyl materials coated with a thin layer of silicone or Teflon, as well as metallic materials.
Evaluation criteria for the adhesion properties and bonding strength of transdermal patches:
General appearance and physical properties: The preparation must be homogeneous, exhibit appropriate adhesion properties, allowing easy application and removal, and must not cause skin irritation.
Uniformity of content: The average content of 10 tested units must fall within the range of 90–110%.
Uniformity of mass of the drug-containing layer: Not more than 2 units may deviate by more than ±5% from the average mass, and no unit may deviate by more than ±10%.
Uniformity of area: Not more than 2 units may deviate by more than ±5% from the average area, and no unit may deviate by more than ±10%.
Identification, assay, and drug release: These tests must comply with the requirements specified in the relevant individual monograph.
Skin irritation test: The results are evaluated by observing and recording differences between the control skin area and the test skin area at 1, 24, 48, and 72 hours after removal and cleaning of the test sample from the rabbit's skin.
In addition, TTS requires adhesion performance evaluation during formulation development. Adhesion performance refers to the ability of the patch to maintain continuous and secure contact with the skin throughout the treatment period. This is a key factor influencing the clinical performance of the TTS. Adhesion evaluation is generally based on fundamental properties, including peel adhesion, release liner peel force, tack, shear adhesion, and cold flow.
Key adhesion evaluation tests:
Peel Adhesion Test: Measures the force required to remove the patch from a standardized test surface.
Release Liner Peel Test: Measures the force required to separate the protective release liner from the adhesive layer before application.
Tack Test: Measures the immediate adhesive strength of the pressure-sensitive adhesive upon light contact with a surface.
Shear Test: Measures the internal cohesive strength of the adhesive matrix under the application of shear force.
Cold Flow Test: Evaluates adhesive leakage or migration beyond the edges of the backing layer or through the protective release liner during storage.
Sign up for our weekly newsletter to get the latest updates.